Detalhes do produto:
Lugar de origem: Alemão
Marca: Rexroth
Certificação: ISO
Número do modelo: DBW10B2-5X/200-6EG24N9K4
Condições de Pagamento e Envio:
Quantidade de ordem mínima: 1
Detalhes da embalagem: CAIXA DE MADEIRA
Tempo de entrega: 2 semanas
Termos de pagamento: Western Union,T/T,D/P,D/A,L/C
Habilidade da fonte: 100

Válvula direcional de alívio eletromagnética Rexroth original importada R900912910 DBW10B2-5X/200-6EG24N9K4

descrição
Máx. Fluxo: até 60 l/min Temperatura da mídia: -20°C a +80°C (óleo mineral)
Modelo: DBW 10 B 2-5X/200-6EG24N9K4 Nº do pedido: R900912910
Tamanho nominal: 10mm
Destacar:

Válvula direcional eletromagnética de Rexroth

,

Válvula de alívio hidráulica REXROTH

,

Válvula original Rexroth DBW10B2-5X

Parâmetro

Especificações

Modelo- Não.

DBW 10 B 2-5X/200-6EG24N9K4

Ordem n.o.- Não.

R900912910

Tipo- Não.

Válvula de alívio de pressão proporcional a accionamento por solenoide

Função- Não.

Reforço/limitação da pressão electricamente proporcional

Tamanho nominal- Não.

10 mm

Pressão ajustável- Não.

200 bar

Tipo de solenoide- Não.

Proporcional, alfinete molhado

Voltagem do solenoide- Não.

24 V DC

Código de solenoide- Não.

6EG24N9K4 (Solenóide proporcional com conector DIN)

Sinalização de controlo- Não.

Análogo (por exemplo, 0-10V, 0-20mA) via amplificador externo

Designação do porto- Não.

P (entrada de pressão), T (saída do reservatório)

Linha de porta- Não.

P e T: M16x2

Interface de montagem- Não.

Tipo cartucho, parafuso

Max. Fluxo- Não.

Até 60 L/min (dependendo da pressão)

Características de controlo- Não.

Específica para a variante B2 (ver ficha de dados)

Conexão elétrica- Não.

DIN 43650 Formulário A, com LED

Material de vedação padrão- Não.

FKM (Viton)

Mídia adequada- Não.

Óleos minerais (HL, HLP de acordo com a DIN 51524), HFA, HFB, fluidos HFC

Temperatura do meio- Não.

-20°C a +80°C (óleo mineral)

Viscosidade dos meios- Não.

10 a 400 mm2/s

Histerese- Não.

≤ ± 3% da pressão máxima (típica)

Fugas- Não.

Fuga zero na posição fechada

Válvula direcional de alívio eletromagnética Rexroth original importada R900912910 DBW10B2-5X/200-6EG24N9K4 0

R901206203 DBW10A1-5X/315U6EW230N9K4
R901076401 DBW10A1-5X/315Y6EG24N9K4
R900770685 DBW10A1-5X/350-6EG24N9K4
R901081986 DBW10A1-5X/350S6EG24N9K4R12
R900731666 DBW10A2-5X/50-6EG24N9K4
R900709700 DBW10A2-5X/50S6EG24N9K4R12
R900618742 DBW10A2-5X/50YS6EG24N9K4R12
R900966799 DBW10A2-5X/50XY6EW230N9K4
R900948450 DBW10A2-5X/100-6EG24N9K4
R900919570 DBW10A2-5X/100-6EW230N9K4
R900952229 DBW10A2-5X/100U6EG24N9K4
R900744546 DBW10A2-5X/100U6EW230N9K4
R900936176 DBW10A2-5X/100U6EW230N9K4V
R900967954 DBW10A2-5X/100X6EG24N9K4
R900778745 DBW10A2-5X/100Y6EG24N9K4
R900714015 DBW10A2-5X/100YU6EG24N9K4
R900955622 DBW10A2-5X/200-6EG24NK4
R900926249 DBW10A2-5X/200-6EG24N9K4
R900934197 DBW10A2-5X/200-6EG24N9K4V
R900708837 DBW10A2-5X/200-6EW230N9K4
R900618747 DBW10A2-5X/200S6EG24N9K4R12
R900961079 DBW10A2-5X/200S6EW230N9K4R12V
R901075701 DBW10A2-5X/200U6EG24N9K4
R901043847 DBW10A2-5X/200U6EW230N9K4
R900971685 DBW10A2-5X/200X6EG24NK4
R900971455 DBW10A2-5X/200X6EG24N9K4
R901086790 DBW10A2-5X/200X6EW230N9K4
R900909516 DBW10A2-5X/200Y6EG24N9K4
R900916162 DBW10A2-5X/200Y6EW230N9K4
R900721105 DBW10A2-5X/200YS6EG24N9K4R12
R900758546 DBW10A2-5X/200YS6EG24N9K4R12V
R901120385 DBW10A2-5X/200YU6EG24N9K4
R900941213 DBW10A2-5X/200XY6EG24N9K4
R900926054 DBW10A2-5X/315-6EG24N9K4
R900958973 DBW10A2-5X/315-6EG24N9K4V
R900922377 DBW10A2-5X/315-6EW230N9K4
R900935532 DBW10A2-5X/315S6EG24N9K4R12
R900954472 DBW10A2-5X/315S6EG24N9K4R12V
R901130713 DBW10A2-5X/315S6EW230N9K4R12
R900781325 DBW10A2-5X/315U6EG24NK4
R900741804 DBW10A2-5X/315U6EG24N9K4
R900772250 DBW10A2-5X/315U6EW230N9K4
R901243992 DBW10A2-5X/315US6EG24N9K4R12
R900726914 DBW10A2-5X/315X6EG24N9K4
R900920436 DBW10A2-5X/315Y6EG24N9K4
R900956639 DBW10A2-5X/315Y6EG24N9K4V
R900937506 DBW10A2-5X/315Y6EW230N9K4
R900765091 DBW10A2-5X/315YS6EG24N9K4R12
R900964379 DBW10A2-5X/315XY6EG24N9K4
R900930684 DBW10A2-5X/350-6EG24NK4
R900974700 DBW10A2-5X/350-6EG24N9K4
R900919859 DBW10A2-5X/350-6EG24N9K4V
R900579624 DBW10A2-5X/350-6EW230N9K4
R901107522 DBW10A2-5X/350-6SMG24N9K4

Fragmentos de informação sobre a válvula de alívio de solenoide da Rexroth DBW10B2-5X/200-6EG24N9K4

  1. P: Como a variante "B2" difere da variante "B1" mencionada anteriormente?

    A:Os sufixos "B1" e "B2" indicam diferentesCurvas de características de desempenhoA versão "B2" tem tipicamente uma relação definida entre o sinal de controlo de entrada (por exemplo, 0-10V) e a pressão de saída resultante que difere da versão "B1".Isto pode estar relacionado com a inclinação da curvaPara um controlo preciso, é essencial utilizar a válvula com a curva característica (B1, B2, etc.) que corresponde aos requisitos de projecto do seu sistema.As especificações exactas são detalhadas na ficha oficial de dados das válvulas.

  2. P: Qual é a função do LED na tomada do solenoide?

    A:O LED integrado serve como um indicador de estado visual. Ele se acende quando a bobina de solenoide está recebendo a corrente elétrica comandada do amplificador proporcional.Confirma a conectividade elétrica básica e que o amplificador está a emitir um sinalMas é.Não, não.Indicar o nível de pressão real ou a qualidade do sinal de controlo.

  3. P: Posso simplesmente ligar um sinal de 0-10V do meu PLC diretamente a esta válvula para controlá-la?

    R: Não, não pode.O solenoide proporcional requer umcorrenteNão é um sinal de tensão.amplificador proporcional(por exemplo, série Rexroth VT-VSPA) é obrigatório. O amplificador toma o comando de tensão do seu PLC (por exemplo, 0-10V), converte-o na corrente precisa necessária para o solenoide,e fornece características como tempos de rampaA ligação directa não funcionará e pode danificar o solenoide.

  4. P: A pressão do sistema está oscilando ou instável quando esta válvula está ativa.

    A:A instabilidade da pressão com uma válvula de alívio proporcional pode ser causada por vários fatores: 1)Configuração incorreta do amplificador(por exemplo, frequência de dither demasiado elevada ou demasiado baixa, ganho demasiado elevado). 2)Ruído eléctricointerferir com o sinal de comando de baixa tensão.Problemas mecânicosO sistema é equipado com um filtro de fase piloto obstruído, uma contaminação na válvula ou uma contrapressão excessiva na saída externa da válvula (Y).frequência naturalVerifique a configuração elétrica, limpe o fluido e certifique-se de que a linha de drenagem não esteja obstruída e livre de pressão.

  5. P: O que significa "/200 " no número do modelo, e a válvula pode ser ajustada mais alto?

    A:O "/200" indica oPressão máxima ajustávelA pressão é definida eletronicamente através do sinal de entrada para o amplificador.Não pode e não deveO sinal eléctrico correspondente a 200 bar é definido pela curva característica da válvula e pela configuração do amplificador.

Contacto
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.

Pessoa de Contato: Mr. liyun

Telefone: +8615280488899

Envie sua pergunta diretamente para nós (0 / 3000)