جزئیات محصول:
|
| وزن: | 21 کیلوگرم | دمای عملیاتی: | -10 درجه سانتیگراد تا +70 درجه سانتیگراد |
|---|---|---|---|
| مواد مهر و موم: | NBR (نیتریل). | قدرت درایو: | 20.5 کیلو وات (در 1450 دور در دقیقه، 160 بار) |
| محدوده سرعت: | 900 - 1800 دور در دقیقه | ||
| برجسته کردن: | Rexroth variable blade pump,Vane pump with warranty,Germany hydraulic vane pump |
||
|
Parameter |
Specification |
|---|---|
|
Manufacturer / Series |
Rexroth PV7-1X Series (Industrial Vane Pump) |
|
Order Code |
R900534508 |
|
Full Model |
PV7-1X/25-45RE01MC0-16 |
|
Pump Type |
Variable Displacement Vane Pump (Open Circuit) |
|
Control Type |
C (Pilot-Operated Pressure Compensator) |
|
Max. Displacement |
45 cm³/rev |
|
Max. Operating Pressure |
160 bar |
|
Frame Size |
BG 25 / NG 45 |
|
Rotation Direction |
Right-hand (R, Clockwise, viewed from shaft end) |
|
Shaft Type |
Cylindrical Shaft (Ø25 mm) with Parallel Key (ISO 3019-2) |
|
Ports |
S (Suction), P (Pressure), L (Case Drain) |
|
Port Connection |
01 (G Pipe Threads, DIN ISO 228) |
|
Mounting Flange |
4-bolt Flange (ISO 3019-2) |
|
Speed Range |
900 – 1800 rpm |
|
Max. Flow |
~66 L/min (at 1450 rpm) |
|
Drive Power |
~20.5 kW (at 1450 rpm, 160 bar) |
|
Seal Material |
NBR (Nitrile) |
|
Hydraulic Fluid |
Mineral oils (HLP), HETG, HEES |
|
Operating Temperature |
-10°C to +70°C |
|
Weight |
Approx. 21 kg |
|
Country of Origin |
Germany |
Q1: What is the function of the "C" control? How does it differ from the "A" control?
A: The "C" control is a pilot-operated (servo) pressure compensator. It uses a small pilot valve to control a large piston, providing faster and more sensitive response compared to the direct-operated "A" control. When system pressure reaches the set value (adjusted via handwheel), the pump quickly de-strokes to near-zero flow, maintaining pressure with minimal energy loss. It is more precise and has less hysteresis than the "A" type.
Q2: What does the "RE01MC0-16" suffix indicate?
A: This code defines the mechanical configuration and settings:
R: Right-hand rotation.
E: Cylindrical shaft with parallel key (ISO 3019-2).
01: Pipe threads (G-threads) for suction and pressure ports.
M: NBR seals, standard for mineral oils.
C: Pilot-operated pressure controller.
0: Standard version.
-16: Zero-stroke pressure adjustment range up to 160 bar.
Q3: What is the key difference between this model (PV7-1X/25-45) and the previous PV7-1X/25-30?
A: The primary difference is the displacement and flow output:
PV7-1X/25-45 (This model): Larger displacement (45 cm³/rev), higher flow output (~66 L/min), and requires more drive power (~20.5 kW). It is designed for applications needing higher flow at 160 bar.
PV7-1X/25-30 (Previous model): Smaller displacement (30 cm³/rev), lower flow (~43.5 L/min), and lower power requirement (~13.7 kW).
Both share the same robust BG25 frame and 160 bar pressure capability.
Q4: What are the critical installation requirements for this pump?
A:
Suction Conditions: Requires a flooded suction. Inlet pressure must be between 0.8 bar (abs) and 2.5 bar to prevent cavitation.
Case Drain (L Port): Must be connected directly to the tank with minimal backpressure (max 2 bar).
Shaft Warning: The shaft is not designed to handle radial or axial loads. Ensure perfect alignment with the motor using a flexible coupling.
Q5: Can this pump be used as a fixed displacement pump?
A: No. The PV7-1X/...C... is inherently a variable displacement pump. Its output flow automatically reduces to zero when system pressure reaches the set value (pressure-holding function). For fixed flow, you would need a gear pump or a fixed vane pump.
تماس با شخص: Mr. liyun
تلفن: +8615280488899