جزئیات محصول:
|
| وزن: | 3.9 کیلوگرم | رتبه حفاظتی: | IP65 |
|---|---|---|---|
| دمای رسانه: | 20- تا 80+ درجه سانتی گراد | رابط نصب: | ISO 4401-05-04-0-94 (CETOP 5، صفحه فرعی NG10) |
| کانکتور برق: | فقط سوکت دوشاخه (K0) – نیاز به دوشاخه جفت گیری جداگانه دارد |
|
Parameter |
Specification |
|---|---|
|
Order Number |
0811404818 |
|
Model |
4WRPE10CB80M-2X/G24K0/A1M-846 |
|
Type |
Direct-operated proportional directional valve with integrated electronics (OBE) |
|
Function |
4/3-way (4 ports, 3 positions) |
|
Spool Type |
B (Positive overlap, industrial) with inductive position feedback (LVDT) |
|
Nominal Size |
NG10 (CETOP 5, Size 10) |
|
Max. Operating Pressure |
P, A, B: 315 bar |
|
Rated Flow |
80 L/min (at Δp = 10 bar per control edge) |
|
Max. Flow |
Approx. 80–100 L/min |
|
Electronics |
Integrated On-Board Electronics (OBE) |
|
Supply Voltage |
24V DC (G24) |
|
Control Signal |
±10 V DC (A1, analog voltage input) |
|
Feedback Signal |
Spool position feedback (LVDT) |
|
Manual Override |
Yes (M = concealed manual override) |
|
Seal Material |
NBR (M) |
|
Electrical Connector |
Plug socket only (K0) – requires separate mating plug |
|
Mounting Interface |
ISO 4401-05-04-0-94 (CETOP 5, NG10 subplate) |
|
Suitable Media |
Mineral oils (HL, HLP), HFC, HFD, biodegradable oils |
|
Media Temperature |
-20°C to +80°C |
|
Viscosity Range |
10 to 800 mm²/s (recommended 20–100 mm²/s) |
|
Ambient Temperature |
-20°C to +60°C |
|
Protection Rating |
IP65 (when mated plug connected) |
|
Weight |
Approx. 3.9 kg |
![]()
| R927000639 4WRPEH6C3B40L -2X/G24K0/F1M |
| R927000641 4WRPEH6C3B04L-2X/G24K0/B5M |
| R927000642 4WRPEH6C3B24L-2X/G24K0/B5M |
| R927000643 4WRPEH6C3B12L-2X/G24K0/B5M |
| R927000644 4WRPEH6C4B24L-2X/G24K0/B5M |
| R927000645 4WRPEH6C3B40P-2X/G24K0/B5M |
| R927000646 4WRPEH6C3B40L-2X/G24K0/B5M |
| R927000905 4WRPEH6CB40L-2X/G24K0/A1M |
| R927000906 4WRPEH6C3B15P-2X/G24K0/A1M |
| R927000909 4WRPEH6C4B25P-2X/G24K0/A1M |
| R927000910 4WRPEH6C4B15P-2X/G24K0/A1M |
| R927000911 4WRPEH6C1B40L-2X/G24K0/A1M |
| R927000920 4WRPEH6CB04L-2X/G24K0/A1M |
| R927000921 4WRPEH6CB40L-2X/G24K0/F1M |
| R927001152 4WRPEH6C1B40P-2X/G24K0/A1M |
| R927001153 4WRPEH6C3B02L-2X/G24K0/A1M |
| R978714494 4WRPEH6CB40L-2X/G24K0/A1M SO43A-1851 |
| R978714502 4WRPEH6C3B40L-2X/G24K0/A1M SO43A-1850 |
| R978716388 4WRPEH6C3B24L-2X/G24K0/A1M SO43A-1849 |
| 0811404001 4WRP10E63S-1X/G24Z4/M |
| 0811404002 4WRP10W63S-1X/G24Z4/M-791 |
| 0811404003 4WRP10E32S-1X/G24Z4/M |
| 0811404004 4WRP10W32S-1X/G24Z4/M-787 |
| 0811404011 REGELVENTIL |
| 0811404016 WEGEVENTIL |
| 0811404019 4WRP10EA63S-1X/G24K4/M-851 |
| 0811404020 4WRP10E63S-1X/G24Z4/M-850 |
| 0811404021 4WRP10EA63S-1X/G24Z4/M-850 |
| 0811404032 4WRPH6KB50L-2X/G24Z4/M |
| 0811404033 4WRPH6C3B04L-2X/G24Z4/M |
| 0811404034 4WRPH6C3B12L-2X/G24Z4/M |
| 0811404035 4WRPH6C3B24L-2X/G24Z4/M |
| 0811404036 4WRPH6C3B40L-2X/G24Z4/M |
| 0811404037 4WRPH6C4B12L-2X/G24Z4/M |
| 0811404038 4WRPH6C4B24L-2X/G24Z4/M |
| 0811404039 4WRPH6C4B40L-2X/G24Z4/M |
FAQ:
Spool Characteristic (B80M)
The B-spool has positive overlap (underlap), which provides good centering and dirt tolerance, making it suitable for general industrial applications. The "80M" indicates an 80 L/min rated flow with a medium (M) flow characteristic (progressive or linear).
Integrated Electronics (OBE)
This valve has on-board electronics (OBE), meaning the amplifier is built into the valve coil housing. It accepts a ±10 V DC (A1) command signal directly and uses LVDT feedback for internal spool position control, eliminating the need for an external amplifier box.
Electrical Connection (K0)
The /K0 suffix indicates that the valve is supplied with a plug socket (female) but no attached cable or plug. You must procure a separate mating plug (e.g., per DIN 43563 or EN 175201-804) to connect the power and signal wires.
Fail-Safe Behavior
This is a double-solenoid, spring-centered valve. In the event of power loss or signal failure, the internal springs return the spool to the central (neutral) position (typically all ports blocked, depending on the spool symbol).
Critical Installation Notes
Plug Requirement: Unlike valves with pre-attached cables, the /K0 version requires you to wire a separate plug. Ensure correct pin assignment for +24V, 0V, and ±10V signal.
Mounting: Use the correct ISO 4401-05 (NG10) subplate to ensure proper port alignment and sealing.
Cleanliness: Maintain oil cleanliness (recommended ISO 4406 19/17/14 or better) to protect the sensitive proportional spool.