제품 상세 정보:
|
| 매개변수: | 설명 | 모델: | Z2DB6VD2-4X/200V |
|---|---|---|---|
| 제품 코드: | R900411314 | 원산지: | 독일 |
| 최대. 압력: | 350 바 |
|
Parameter |
Description |
|---|---|
|
Model |
Z2DB6VD2-4X/200V |
|
Product Code |
R900411314 |
|
Type |
Stacked, two-way cartridge relief/unloading valve |
|
Origin |
Germany |
|
Mounting |
Sandwich / Stacked |
|
Max. Pressure |
350 bar |
|
Set Pressure |
200 bar |
|
Flow |
60 L/min |
|
Pilot Stage |
VD2 (two-way, two-position pilot valve) |
|
Control |
4X: Solenoid, external pilot supply & drain |
|
Voltage |
24V DC (standard) |
|
Function |
Solenoid-controlled pressure relief/unloading, typically installed in combination with other valves. |
![]()
| R900409898 ZDB6VP2-4X/315V |
| R900409896 ZDB6VB2-4X/315V |
| R900409893 ZDB6VA2-4X/315V |
| R900409889 ZDB6VA2-4X/100V |
| R900409886 ZDB6VA2-4X/200V |
| R900409854 ZDB6VB2-4X/200V |
| R900409847 ZDB6VP2-4X/50V |
| R900409844 ZDB6VP2-4X/200V |
| R900406615 ZDB6VA2-4X/50V |
| R900403470 ZDB6VA3-4X/200V |
| R900402018 ZDB10VP1-4X/315V |
| R900967527 ZDB10VP1-4X/100 |
| R900967507 ZDB6VB1-4X/100 |
| R900906981 ZDB10VA3-4X/100 |
| R900248279 ZDBEE6VP3-1X/50G24NK31M |
| R900246322 ZDBE6VP2-1X/200G24NK4V |
| R900244964 ZDBEE6VP2-1X/100G24NK31M |
| R900596905 ZDB10VP1-4X/100V |
| R900586621 ZDB6VP1-4X/100V |
| R900583801 ZDB6VA1-4X/50V |
| R900564564 ZDBK6VP2-1X/210V |
| R900564561 ZDBK6VB2-1X/210V |
| R900564530 ZDBK10VP2-1X/210V |
| R900561458 ZDB6VP2-4X/350V |
| R900551788 ZDB6VB1-4X/315V |
| R900522027 ZDB6VA1-4X/315V |
| R900509893 ZDB6VA1-4X/315 |
| R900506373 ZDB10VB3-4X/100V |
| R900501402 ZDBK6VA2-1X/100V |
| R900501258 ZDB10VA1-4X/200 |
| R900449008 ZDB6VP1-4X/50V |
| R900440160 ZDB6VB3-4X/50V |
| R900437441 ZDB6VA2-4X/100 |
| R900433646 ZDB6VA1-4X/200V |
| R900432106 ZDB10VA2-4X/50 |
| R900431678 ZDB6VA2-4X/50 |
| R900431401 ZDB6VB2-4X/100 |
| R900431071 ZDB6VA2-4X/315 |
| R900430984 ZDB10VA2-4X/315 |
| R900429509 ZDB6VB2-4X/200 |
| R900428468 ZDB10VP2-4X/200 |
| R900428339 ZDB6VP2-4X/200 |
| R900427434 ZDB10VA2-4X/100 |
| R900425927 ZDB10VP2-4X/315 |
| R900425681 ZDB10VB2-4X/315 |
| R900424537 ZDB10VA2-4X/100V |
| R900423274 ZDB6VP2-4X/100 |
| R900422752 ZDB10VP2-4X/50V |
| R900422261 ZDB10VB2-4X/200 |
| R900422215 ZDB10VB2-4X/200V |
| R900422189 ZDB10VA2-4X/200V |
| R900422089 ZDB6VP3-4X/200 |
| R900422075 ZDB6VP2-4X/315 |
| R900422073 ZDB10VB2-4X/100 |
| R900422061 ZDB6VB2-4X/315 |
| R900409959 ZDB10VP2-4X/100V |
| R900409958 ZDB10VP2-4X/315V |
| R900409956 ZDB10VB2-4X/315V |
| R900409955 ZDB10VA2-4X/315V |
| R900409951 ZDB10VB2-4X/100V |
| R900409936 ZDB6VB2-4X/100V |
| R900409933 ZDB6VP2-4X/100V |
| R900409898 ZDB6VP2-4X/315V |
| R900409896 ZDB6VB2-4X/315V |
| R900409893 ZDB6VA2-4X/315V |
What is it?
A stacked, solenoid-controlled two-way cartridge relief/unloading valve.
Key specs?
Type: Stacked, two-way relief/unloading valve.
Pressure: Set to 200 bar.
Flow: 60 L/min.
Control: Solenoid, 24V DC.
How does it work?
Installed in a valve stack, it unloads the pump to tank when its solenoid is energized, saving energy. It resets to maintain system pressure (200 bar) when de-energized.
Where is it used?
As an integrated unloading component in hydraulic valve stacks for energy-saving applications.
What is "VD2"?
Indicates a two-way, two-position pilot valve design, defining its specific control characteristics.
Troubleshooting tips?
Fails to unload: Check solenoid power and coil.
Pressure issues: Verify pilot supply pressure and check for contamination.
External leaks: Inspect seals between stacked plates.