제품 상세 정보:
|
| 최대 유량: | 60 L/min | 디자인: | 습식 핀 솔레노이드; 서브플레이트 장착 |
|---|---|---|---|
| 모델: | 4WE10J5X/HG24N9K4/M. | 보호등급(코일): | IP65 표준 |
| 권장 점도 범위: | 10~400mm²/초 | ||
| 강조하다: | Rexroth solenoid directional valve,Rexroth hydraulic valve with warranty,4WE10J5X hydraulic solenoid valve |
||
|
Parameter |
Value / Description |
|---|---|
|
Valve Type |
Solenoid-operated directional control valve |
|
Model |
4WE 10 J5X/HG24N9K4/M |
|
Design |
Wet-pin solenoid; Subplate mounting |
|
Connection Size (P/A/B/T) |
G 1/4" |
|
Nominal Size |
10 mm |
|
Maximum Operating Pressure |
315 bar |
|
Maximum Flow Rate |
60 l/min |
|
Number of Positions/Ways |
4-way, 3-position |
|
Spool Type (J5X) |
Pressure port P blocked, work ports A & B connected to tank T in center position ("Tandem center" or "Float center") |
|
Control Method |
Single solenoid, with spring return to center |
|
Solenoid Specification (HG24N9K4) |
24V DC; with manual override; plug connector (DIN 43650 Form A) |
|
Operating Voltage |
24V DC |
|
Power Consumption |
Typically ~22W (Confirm with official datasheet) |
|
Protection Class (Coil) |
IP65 standard |
|
Duty Cycle |
100% |
|
Mounting |
According to ISO 4401-05 (CETOP 5) |
|
Weight (approx.) |
~3.0 kg (with coil) |
|
Housing Material |
Aluminum alloy |
|
Sealing Material |
Nitrile rubber (NBR) standard; FKM optional |
|
Fluid Temperature Range |
-20 °C to +80 °C (with NBR seals) |
|
Recommended Viscosity Range |
10 to 400 mm²/s |
|
Fluid Compatibility |
Mineral oils (HL, HLP per ISO 6743-4) |
|
Filtration Requirement |
Cleanliness class 20/18/15 per ISO 4406 (recommended) |
![]()
| R901278760 4WE10D5X/EG24N9K4/M |
| R901278763 4WE10D5X/OFEG24N9K4/M |
| R901339383 4WE10D5X/EG220N9K4/M |
| R901278744 4WE10J5X/EG24N9K4/M |
| R901391203 4WE10C5X/HG24N9K4/M |
| R901390857 4WE10E5X/HG24N9K4/M |
| R901401552 4WE10J5X/HG24N9K4/M |
| R901391161 4WE10L5X/HG24N9K4/M |
| R901391194 4WE10U5X/HG24N9K4/M |
| R901427832 4WE10G5X/HG24N9K4/M |
| R901427828 4WE10H5X/HG24N9K4/M |
| R901401553 4WE10M5X/HG24N9K4/M |
| R901391202 4WE10Y5X/HG24N9K4/M |
| R900952630 4WEH10E4X/6EG24N9ETK4/B10 |
| R900948924 4WEH10J4X/6EG24N9ETK4/B10 |
| R901531045 4WEH16D1X/6HG24N9EK4/B10 |
| R901108754 4WEH16E7X/6HG24N9ETK4/B10 |
| R901108808 4WEH16J7X/6HG24N9ETK4/B10 |
| R901480132 4WEH16J7X/6HG24N9ETK4/B10-910 |
| R900937356 4WEH22D7X/6EG24N9ETK4/B10 |
| R900943534 4WEH22E7X/6EG24N9ETK4/B10 |
| R901108960 4WEH22J7X/6HG24N9ETK4/B10 |
| R900932049 4WEH22J7X/6EG24N9ETK4/B10 |
| R901119654 H-4WEH25E6X/6HG24N9ETK4/B10D3 |
| R900932940 H-4WEH25J6X/6EG24N9ETK4/B10D3 |
| 0532004204 PRESS RELIEF VALVE 160 BAR |
| R900438939 DBDS6K1X/400V |
| R900769564 DBDS6K1X/190E |
| R900769414 DBDS10K1X/160E |
| R900424149 DBDS10K1X/200 |
| R900424183 DBDH10K1X/315 |
| R900424152 DBDS10K1X/400 |
| R900424269 DBDS20K1X/200 |
| R900424286 DBDS30K1X/200 |
| 0811109135 ZDBY6DA2-1X/80V/60 |
| R900409844 ZDB6VP2-4X/200V |
| R900409898 ZDB6VP2-4X/315V |
| R900426329 ZDB6VA2-4X/200 |
| R900411314 Z2DB6VD2-4X/200V |
| R900409955 ZDB10VA2-4X/315V |
| R900409958 ZDB10VP2-4X/315V |
| R900411358 Z2DB10VD2-4X/200V |
| R900505052 DB10-1-5X/200 |
| R900598998 DB10-1-5X/315 |
| R900590334 DB10-2-5X/315 |
| R900502117 DB20-1-5X/200 |
| R900587346 DB20-1-5X/315 |
| R983037993 DBDH10G1X/315 |
| R900425660 DBDS10P1X/400 |
| R900424277 DBDS20P1X/200 |
| R900424279 DBDS20P1X/400 |
| R900923103 DBW10B1-5X/200-6EG24N9K4 |
| R900912910 DBW10B2-5X/200-6EG24N9K4 |
| R900920863 DBW10B1-5X/315-6EG24N9K4 |
| R900906285 DBW10B2-5X/315-6EG24N9K4 |
| R901216280 DAW30B2-5X/200-FS6EG24N9K4 |
| R900479509 DR6DP1-5X/25YM |
| R900450964 DR6DP2-5X/75YM |
| R901418087 Z3DR6VP3-1X/315V |
Q1: What is the main function of the "J5X" spool?
A: The "J5X" spool provides a "tandem center" or "float center" function. In the neutral (spring-centered) position, the pressure port (P) is blocked, and both actuator ports (A and B) are connected to the tank (T). This allows the connected hydraulic cylinder or motor to move freely ("float") if an external force is applied.
Q2: How is this valve's center position different from others?
A: It differs from the "C5X" (P to T, A/B blocked) and "D5X" (all ports blocked). The "J5X" is designed for applications where the actuator must be free to move when the valve is in neutral, such as for clamping, positioning, or in circuits with pilot-operated checks.
Q3: How is the valve controlled?
A: It is controlled by a single 24V DC solenoid ("HG24N9K4" coil). When energized, the solenoid shifts the spool. When de-energized, internal springs return the spool to the tandem-center (float) position. A manual override is provided for testing.
Q4: What are the key pressure and flow ratings?
A: Maximum operating pressure: 315 bar. Maximum recommended flow rate: 60 liters per minute.
Q5: What are the electrical specifications?
A: The solenoid operates on 24V DC, with a protection class of IP65. For the exact power consumption, inrush current, and duty cycle, please consult the official data sheet.
담당자: Mr. liyun
전화 번호: +8615280488899