제품 상세 정보:
|
| 연료: | 디젤, 유압, 오일, 전기 진공 펌프, 가솔린 | 이론: | 회전식 펌프, 축류 펌프, 왕복 펌프, 진공 펌프, 유압 펌프 |
|---|---|---|---|
| 재료: | 무쇠, 스테인리스, 주철/강철/청동/연성철 등 | 보증: | 1년,6개월-12개월,12개월,1년,3개월 또는 1년 |
| 특징: | 고효율, 장수 | 이름: | 렉스로스 피스톤 펌프, 90R100 펌프, 굴삭기 펌프 부품 렉스로스 펌프 유압 펌프 |
| 기원: | 산동, 중국, 100% 오리지널 렉스로스 기어 펌프 | ||
| 강조하다: | Rexroth hydraulic proportional valve,electromagnetic directional valve Rexroth,hydraulic valve with warranty |
||
4WRA10W60-22/G24K4/V
4WRA10E1-60-22/G24K4/V
4WRA6W30-22/G24K4/V
| Complete Model Example | Model Code Breakdown | Core Configuration Parameters | Release Status |
|---|---|---|---|
| 4WRE 6 E04-2X/V | 4WRE: Base Model 6: Nominal Size E: 4/3 3-position 4-way (spring-centered) 04: Rated Flow 4L/min (Δp=10bar) 2X: Component Series V: Seal Material (FKM Fluororubber) |
Valve Type: 4/3 3-position 4-way Flow Rate: 4L/min Seal: FKM Power Supply: Compatible with DC24V Interface: Supports ±10V/4-20mA |
Officially Released (Mass Production) |
| 4WRE 6 E08-2X/V | 4WRE: Base Model 6: Nominal Size E: 4/3 3-position 4-way (spring-centered) 08: Rated Flow 8L/min (Δp=10bar) 2X: Component Series V: Seal Material (FKM Fluororubber) |
Valve Type: 4/3 3-position 4-way Flow Rate: 8L/min Seal: FKM Power Supply: Compatible with DC24V Interface: Supports ±10V/4-20mA |
Officially Released (Mass Production) |
| 4WRE 6 E16-2X/V | 4WRE: Base Model 6: Nominal Size E: 4/3 3-position 4-way (spring-centered) 16: Rated Flow 16L/min (Δp=10bar) 2X: Component Series V: Seal Material (FKM Fluororubber) |
Valve Type: 4/3 3-position 4-way Flow Rate: 16L/min Seal: FKM Power Supply: Compatible with DC24V Interface: Supports ±10V/4-20mA |
Officially Released (Mass Production) |
| 4WRE 6 E32-2X/V | 4WRE: Base Model 6: Nominal Size E: 4/3 3-position 4-way (spring-centered) 32: Rated Flow 32L/min (Δp=10bar) 2X: Component Series V: Seal Material (FKM Fluororubber) |
Valve Type: 4/3 3-position 4-way Flow Rate: 32L/min Seal: FKM Power Supply: Compatible with DC24V Interface: Supports ±10V/4-20mA |
Officially Released (Mass Production) |
| 4WRE 6 J08-2X/V | 4WRE: Base Model 6: Nominal Size J: 4/2 2-position 4-way 08: Rated Flow 8L/min (Δp=10bar) 2X: Component Series V: Seal Material (FKM Fluororubber) |
Valve Type: 4/2 2-position 4-way Flow Rate: 8L/min Seal: FKM Power Supply: Compatible with DC24V Interface: Supports ±10V/4-20mA |
Officially Released (Mass Production) |
| 4WRE 6 E08-2X/VJ | 4WRE: Base Model 6: Nominal Size E: 4/3 3-position 4-way (spring-centered) 08: Rated Flow 8L/min (Δp=10bar) 2X: Component Series V: Seal Material (FKM Fluororubber) J: Special Protection (Seawater-Resistant) |
Valve Type: 4/3 3-position 4-way Flow Rate: 8L/min Seal: FKM Protection: Seawater corrosion resistance Power Supply: Compatible with DC24V Interface: Supports ±10V/4-20mA |
Officially Released (Specialized Mass Production) |
4WREE10EA75-2X/G24K31/A1V
4WREE10WA50-2X/G24K31/A1V
4WREE10E50-2X/G24K31/F1V
4WREE10V75-2X/G24K31/F1V
4WREE10WA75-2X/G24K31/A1V
4WREE10W25-2X/G24K31/F1V
4WREE10V25-2X/G24K31/A1V
4WREE10EA50-2X/G24K31/A1V
4WREE10E25-2X/G24K31/F1V
4WREE10E75-2X/G24K31/F1V
4WREE10E1-25-2X/G24K31/F1V
4WREE10E1-50-2X/G24K31/F1V
4WREE10E1-75-2X/G24K31/F1V
4WREE10V25-2X/G24K31/F1V
4WREE10W50-2X/G24K31/F1V
4WREE10E75-2X/G24K31/A1V
4WREE10E1-75-2X/G24K31/A1V
4WREE10WA25-2X/G24K31/A1V
4WREE10EA25-2X/G24K31/A1V
4WREE10E50-2X/G24K31/A1V
4WREE6EA08-2X/G24K31/A1V
4WREE6E1-32-2X/G24K31/F1V
4WREE6EA16-2X/G24K31/F1V
4WREE6E1-16-2X/G24K31/F1V
4WREE6E1-08-2X/G24K31/F1V
4WREE6E32-2X/G24K31/F1V
4WREE6E16-2X/G24K31/F1V
4WREE6WA32-2X/G24K31/A1V
4WREE6WA16-2X/G24K31/A1V
4WREE6WA08-2X/G24K31/A1V
4WREE6EA32-2X/G24K31/A1V
4WREE6EA16-2X/G24K31/A1V
4WREE6W1-32-2X/G24K31/A1V
4WREE6V16-2X/G24K31/F1V
4WREE6WA32-2X/G24K31/F1V
4WREE6W32-2X/G24K31/F1V
4WREE6W1-32-2X/G24K31/F1V
4WREE6E08-2X/G24K31/F1V
4WREE6V32-2X/G24K31/F1V
4WREE6W16-2X/G24K31/F1V
4WREE6EA08-2X/G24K31/F1V
4WREE6EA32-2X/G24K31/F1V
4WREE6WA08-2X/G24K31/F1V
4WREE6WA16-2X/G24K31/F1V
4WREE10E25-2X/G24K31/A1V
4WREE6W08-2X/G24K31/F1V
4WREE6W1-08-2X/G24K31/F1V
4WREE6W1-16-2X/G24K31/F1V
4WREE6V08-2X/G24K31/F1V
4WREE6W32-2X/G24K31/A1V
4WRE6W16-2X/G24K4/V
4WREE6W1-08-2X/G24K31/A1V
4WREE6W16-2X/G24K31/A1V
4WREE6W08-2X/G24K31/A1V
4WREE6V32-2X/G24K31/A1V
4WREE6V16-2X/G24K31/A1V
4WREE6E1-32-2X/G24K31/A1V
4WREE6E1-16-2X/G24K31/A1V
4WREE6E1-08-2X/G24K31/A1V
4WRAE10WA30-22/G24K31/F1V
4WRAE10WA60-22/G24K31/A1V
4WRE6E1-08-2X/G24K4/V
4WRE6V32-2X/G24K4/V
4WRAE10EA60-22/G24K31/F1V
4WREE6V08-2X/G24K31/A1V
4WRAE10WA60-22/G24K31/F1V
4WRE6E08-2X/G24K4/V
4WRE6E16-2X/G24K4/V
4WRE6E1-16-2X/G24K4/V
4WRE6V08-2X/G24K4/V
4WRE6W32-2X/G24K4/V
4WREE6E32-2X/G24K31/A1V
4WRAE10WA30-22/G24K31/A1V
4WRE6W1-08-2X/G24K4/V
4WRE6E32-2X/G24K4/V
4WRE6E1-32-2X/G24K4/V
4WRE6V16-2X/G24K4/V
4WRE6W08-2X/G24K4/V
4WREE6W1-16-2X/G24K31/A1V
4WRAE10EA60-22/G24K31/A1V
4WRAE10E30-22/G24K31/F1V
4WRAE6EA15-22/G24K31/F1V
4WREE10W1-50-2X/G24K31/A1V
4WRAE6EA07-22/G24K31/F1V
4WRAE6WA07-22/G24K31/F1V
4WRAE6WA15-22/G24K31/F1V
4WRAE6WA30-22/G24K31/A1V
4WRAE6WA30-22/G24K31/F1V
4WRAE10E30-22/G24K31/A1V
4WRAE10W60-22/G24K31/F1V
4WRAE6EA30-22/G24K31/A1V
4WRAE6EA30-22/G24K31/F1V
4WRAE6WA15-22/G24K31/A1V
4WRAE10E1-30-22/G24K31/A1V
4WRAE10EA30-22/G24K31/A1V
4WRAE10E1-60-22/G24K31/A1V
4WRAE10E1-60-22/G24K31/F1V
4WRAE10W1-30-22/G24K31/F1V
4WRAE10W1-60-22/G24K31/A1V
4WRAE10W1-60-22/G24K31/F1V
4WRAE10EA30-22/G24K31/F1V
4WRAE6WA07-22/G24K31/A1V
4WRAE10E60-22/G24K31/A1V
4WRAE10E60-22/G24K31/F1V
4WRAE10E1-30-22/G24K31/F1V
4WRAE10W30-22/G24K31/A1V
4WRAE10W30-22/G24K31/F1V
4WRAE10W60-22/G24K31/A1V
4WRAE10W1-30-22/G24K31/A1V
4WRAE6EA07-22/G24K31/A1V
4WRAE6W30-22/G24K31/A1V
4WRAE6W1-30-22/G24K31/F1V
4WRAE6W1-30-22/G24K31/A1V
4WRAE6W1-15-22/G24K31/F1V
4WRAE6W1-15-22/G24K31/A1V
4WRAE6W1-07-22/G24K31/F1V
4WRAE6W1-07-22/G24K31/A1V
4WRAE6W15-22/G24K31/F1V
4WRAE6W30-22/G24K31/F1V
4WRAE6E15-22/G24K31/F1V
4WRAE6E15-22/G24K31/A1V
4WRAE6E30-22/G24K31/A1V
4WRA10WA60-22/G24K4/V
4WRA10EA60-22/G24K4/V
4WRAE6W07-22/G24K31/F1V
4WRAE6E1-30-22/G24K31/F1V
4WRAE6E1-15-22/G24K31/A1V
4WRA10EA30-22/G24K4/V
Optimal viscosity is 20-40 mm²/s (cSt). Viscosity below 10 mm²/s may cause leakage, while viscosity above 100 mm²/s may increase pressure drop and reduce response time.
Yes, a 25 μm absolute filter (β100 ≥ 75) is mandatory in the supply line to prevent contamination of the valve's internal components.
Yes, water contamination (exceeding 0.1%) can cause corrosion, seal degradation, and clogging. Use water-separating filters and monitor fluid moisture levels.
Follow ISO 4406 Class 18/16/13 (maximum 1300 particles ≥4 μm, 160 particles ≥6 μm, 20 particles ≥14 μm per mL).
Yes, all 4WREE valves meet CE requirements for electromagnetic compatibility (EMC) and machinery safety (Directive 2006/42/EC).
담당자: Mr. liyun