logo
Casa ProdottiPompa idraulica Rexroth

High-Pressure Quantitative Hydraulic Gear Pump with Up to 500 l/min Flow Rate and 1000 cc/rev Displacement

Sono ora online in chat

High-Pressure Quantitative Hydraulic Gear Pump with Up to 500 l/min Flow Rate and 1000 cc/rev Displacement

High-Pressure Quantitative Hydraulic Gear Pump with Up to 500 l/min Flow Rate and 1000 cc/rev Displacement
High-Pressure Quantitative Hydraulic Gear Pump with Up to 500 l/min Flow Rate and 1000 cc/rev Displacement High-Pressure Quantitative Hydraulic Gear Pump with Up to 500 l/min Flow Rate and 1000 cc/rev Displacement High-Pressure Quantitative Hydraulic Gear Pump with Up to 500 l/min Flow Rate and 1000 cc/rev Displacement

Grande immagine :  High-Pressure Quantitative Hydraulic Gear Pump with Up to 500 l/min Flow Rate and 1000 cc/rev Displacement

Dettagli:
Luogo di origine: Germania
Marca: Rexroth
Certificazione: ISO
Numero di modello: PGH5-2X/100Re11vu2 PGH5-2X/063RR11VU2 PGH4-2X/080RR07VU2 PGH4-2X/050RF11VK0 PGH5-3X/100RR11VU2
Termini di pagamento e spedizione:
Quantità di ordine minimo: 1
Prezzo: 2
Imballaggi particolari: Scatola di legno
Tempi di consegna: 2 settimane
Termini di pagamento: Moneygram, Western Union, T/T, D/P, D/A, L/C.
Capacità di alimentazione: 100

High-Pressure Quantitative Hydraulic Gear Pump with Up to 500 l/min Flow Rate and 1000 cc/rev Displacement

descrizione
WhatsApp: +85267220981 Portata: Fino a 500 l/min
Spostamento: Fino a 1000 cc/giro Applicazione: fuoco
Data di consegna: 5 giorni Garanzia: Un anno
Certifisaarion: ISO9001 Connessione di ingresso: Filettato o flangiato
Tipo: Pompa a pistone assiale Compatibilità fluida: Olio minerale
Evidenziare:

High-Pressure Hydraulic Gear Pump

,

Quantitative Hydraulic Gear Pump

,

500 l/min Flow Rate Gear Pump

Quantitative High-Pressure Industrial Hydraulic Pump
Product Models
PGH5-2X/100RE11VU2 PGH5-2X/063RR11VU2 PGH4-2X/080RR07VU2 PGH4-2X/050RF11VK0 PGH5-3X/100RR11VU2
Product Specifications
Brand Name Rexroth
Place of Origin Germany
Warranty 12 Months
Video Outgoing-Inspection Provided
Machinery Test Report Provided
Application Machinery Repair Shops
Material Iron
Condition Original
Quality 100% Tested Great Performance
Certification ISO
Feature Long Life Low Noise
Function Filter Diesel Oil
Power Hydraulic Power
Payment Term T/T 100%
Product Image
High-Pressure Quantitative Hydraulic Gear Pump with Up to 500 l/min Flow Rate and 1000 cc/rev Displacement 0
Available Models
PGH5-3X/160RR11VU2 | PGH5-2X/160RE07VU2 | PGH4-2X/050RE11VE4 | PGH3-1X/016RF07MK0 PGH5-3X/160RE11WU2 | PGH5-2X/125RR11VU2 | PGH4-2X/040RE11VU2 | PGH3-1X/016RE07ME4 PGH5-3X/160RE11VU2 | PGH5-2X/125RE11VU2 | PGH4-2X/032RR11VU2 | PGH3-1X/016LE07MU2 PGH5-3X/160RE11VE4 | PGH5-2X/125RE11VE4 | PGH4-2X/032RE11VU2 | PGH3-1X/010RE07MU2 PGH5-3X/125RE11VU2 | PGH5-2X/100RE11VE4 | PGH4-2X/032RE11VE4 | PGH2-X/008LR07VU2 PGH5-3X/125RE11VE4 | PGH5-2X/100LF11VK0 | PGH4-2X/025RE11VU2 | PGH2-X/008LE07VU2 PGH5-3X/125RE11VE4 | PGH5-2X/080RR18VU2 | PGH4-2X/025RE11VU2 | PGH2-X/006RE07VU2 PGH5-3X/100RE11VU2 | PGH5-2X/080RE11VE4 | PGH4-2X/025RE11VE4 | PGH2-X/005RR07VU2 PGH5-3X/080RR11VU2 | PGH5-2X/063RR11VU2 | PGH4-2X/020RE11WU2 | PGH2-2X/008RR07WU2 PGH5-3X/080LR11VU2 | PGH5-2X/063RE11VU2 | PGH4-2X/020RE11VU2 | PGH2-2X/008RE07WU2 PGH5-3X/063RR11WU2 | PGH5-2X/063RE11VE4 | PGH4-2X/020LR18VU2 | PGH2-2X/008RE07VU2 PGH5-3X/063RR11VU2 | PGH5-21/160RE07VU2 | PGH4-21/050RE11VE4 | PGH2-2X/008LR07VU2 PGH5-3X/063RR11-A521 | PGH5-21/125RE11VE4 | PGH4-21/040RE11VU2 | PGH2-2X/008LE07VU2 PGH5-3X/063RE11VU2 | PGH5-21/080RE11VU2 | PGH4-21/032RE11VE4 | PGH2-2X/006RE07VU2 PGH5-30/250RE07VU2 | PGH4-3X/050RE11VU2 | PGH4-21/025RE11VU2 | PGH2-2X/005RR07VU2 PGH5-30/080RR11VU2 | PGH4-3X/020RR11VU2 | PGH3-2X/016RE07VU2 | PGH2-2X/005RE07VU2 PGH5-30/080RE11VU2 | PGH4-2X/100RE07VU2 | PGH3-2X/013RR07VU2 | PGH2-1X/006RE07MU2 PGH5-30/063RE11VU2 | PGH4-2X/080RF07VK0 | PGH3-2X/013RE07VU2 | PGH2-1X/006RE07ME4 PGH5-2X/250RE07VE4 | PGH4-2X/080LF47VK0 | PGH3-2X/011RE07VU2 | PGH2-1X/005RE07MU2
Frequently Asked Questions
Cavitation Issues

Cavitation can cause pressure fluctuations and must be addressed by ensuring proper suction conditions.

Pump Overheating or Noise
  • Overheating: Ensure the fluid viscosity is correct, the system cooler is functioning, and the pump is not overloaded. Check for restrictions in the discharge line.
  • Noise/Vibration: This can indicate cavitation (check suction side), air in the fluid (bleed the system), mechanical wear in bearings or gears, or misalignment between the pump and drive motor. Correct the alignment if necessary.
Maintenance Practices
  • Regular Inspection: Perform visual checks for leaks, unusual noises, and overheating.
  • Fluid Maintenance: Use clean, recommended fluid and monitor its condition. Regularly check and replace suction and pressure filters.
  • Lubrication: Ensure bearings are properly lubricated according to manufacturer specifications.
  • Seal and Connection Check: Inspect shaft seals and pipe connections for leaks and tighten or replace them as needed.
  • Alignment Check: Periodically verify the alignment between the pump and the drive motor.
Technical Support

Yes, most suppliers and manufacturers offer technical support. For genuine replacement parts (e.g., seals, gears, bearings) and specific troubleshooting guidance for your PGH model, it is recommended to contact the supplier or Bosch Rexroth directly.

Warranty and Lead Times

Warranty terms can vary by supplier but are often around 60 days for new units. Standard production lead times for MOQ quantities are typically around 15 days, but this can vary based on the product and order size. Always confirm these details with your supplier.

Contact: whatsapp | +85267220981 | email | yli97584@gmail.com

Dettagli di contatto
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.

Persona di contatto: Mr. liyun

Telefono: +8615280488899

Invia la tua richiesta direttamente a noi (0 / 3000)