Detail produk:
|
| Penggunaan: | Minyak, pompa piston hidrolik | Aplikasi: | Pengukuran, Lainnya, Sistem Hidraulik, pompa hidrolik, excavator |
|---|---|---|---|
| Bahan bakar: | Diesel, hidrolik, oli, pompa vakum listrik, Bensin | Teori: | Pompa Putar, Pompa Aliran Aksial, Pompa Bolak-balik, Pompa Vakum, pompa hidrolik |
| Nama: | Pompa Piston Rexroth, pompa 90R100, bagian pompa excavator, pompa hidrolik, pompa rexroth | Asal: | Shandong, Tiongkok, 100% Pompa Roda Gigi Rexroth Asli |
| Menyoroti: | Rexroth hydraulic proportional valve,German made Rexroth solenoid valve,Rexroth directional valve with warranty |
||
0811404824 4WRPEH10C4B 50P–2X/G24K0/A1M
0811404825 4WRPEH10C4B100P–2X/G24K0/A1M
0811404828 4WRPEH10C1B 50P–2X/G24K0/A1M
German made Rexroth hydraulic proportional solenoid directional valve
| Selection Dimension | Specific Parameters/Options | Description |
|---|---|---|
| Model Designation | 4WRE | Basic model: Direct-acting proportional directional valve with electrical position feedback and no integrated electronics (OBE) |
| Integrated Electronics (OBE) | No Code | Standard configuration without integrated electronics; external amplifier required (to be ordered separately) |
| Nominal Size | 6 | Core size with component series 2X; mounting dimensions comply with Series 20-29 standards |
| Valve Core Type | 4/2 (2-position 4-way), 4/3 (3-position 4-way) | 4/3 type features spring-centered spool for automatic reset when de-energized; suitable for different oil circuit directional control needs |
| Rated Flow (Δp=10bar) | 4L/min (Code 04), 8L/min (Code 08), 16L/min (Code 16), 32L/min (Code 32) | Flow rates distinguished by corresponding codes; matched to hydraulic system flow requirements |
| Seal Material | V (FKM Fluororubber) | Default FKM material; compatible with mineral oil and other hydraulic fluids to ensure sealing performance |
| Power Supply Voltage | G24 (DC 24V) | Suitable for industrial standard DC power supply; meets proportional solenoid drive requirements |
| Electrical Interface | A1 (±10V Voltage Input), F1 (4-20mA Current Input) | Two interface options available; compatible with PLCs, computers, and other control signal sources |
| Electrical Connection | K4 (No Plug) | Plug compliant with DIN EN 175301-803 standard required (to be ordered separately) |
| Special Protection | J (Seawater-Resistant) | Only available for Size 6; suitable for marine-related or humid/corrosive working conditions |
| Mounting Standard | ISO 4401 | Panel mounting with standard mounting hole pattern; compatible with universal hydraulic system manifold layouts |
| Maximum Working Pressure | 315bar | Suitable for most medium-to-high pressure industrial hydraulic scenarios (e.g., hydraulic actuators in machine tools, automated production lines) |
4WRA6E30-22/G24K4/V
4WRA6E07-22/G24K4/V
4WRA6W1-15-22/G24K4/V
4WRA10E60-22/G24K4/V
4WRA6WA07-22/G24K4/V
4WRA6EA15-22/G24K4/V
4WRA6WA30-22/G24K4/V
4WRA6EA07-22/G24K4/V
4WRA6EA30-22/G24K4/V
4WRA6W1-30-22/G24K4/V
4WRA6W1-07-22/G24K4/V
4WRA10W60-22/G24K4/V
4WRA10E1-60-22/G24K4/V
4WRA6W30-22/G24K4/V
4WRA10W30-22/G24K4/V
4WRA10E30-22/G24K4/V
4WRA10E1-30-22/G24K4/V
4WRAP6W7-02-3X/G24K4/V
4WRZ32W9-520-70/6EG24N9TK4/D3M
4WRZ32E3-360-70/6EG24N9K4/M
4WRZ25E3-325-7X/6EG24N9ETK4/M
4WRZ25E3-220-7X/6EG24N9TK4/M
4WRZ16W6A180-70/6EG24N9EK4/D3M
4WRZ16E1-150-70/6EG24N9ETK4/D3M
4WRE10W50-2X/G24K4/V
4WREE6E16-2X/G24K31/A1V
4WREE6E08-2X/G24K31/A1V
4WRE10WA75-2X/G24K4/V
4WRE10WA50-2X/G24K4/V
4WRE10WA25-2X/G24K4/V
4WRE10EA75-2X/G24K4/V
4WRE10EA50-2X/G24K4/V
4WRE10EA25-2X/G24K4/V
4WRE10W1-75-2X/G24K4/V
4WRE10W1-50-2X/G24K4/V
4WRE10W1-25-2X/G24K4/V
4WRE10W75-2X/G24K4/V
4WRE10E1-25-2X/G24K4/V
4WRE6W1-32-2X/G24K4/V
4WRE10V75-2X/G24K4/V
4WRE10V50-2X/G24K4/V
4WRE10V25-2X/G24K4/V
4WRE10E1-75-2X/G24K4/V
4WRE10E1-50-2X/G24K4/V
4WRE10E50-2X/G24K4/V
4WRE10E25-2X/G24K4/V
4WRE6WA16-2X/G24K4/V
4WRE6WA08-2X/G24K4/V
4WRE6EA32-2X/G24K4/V
4WRE6EA16-2X/G24K4/V
4WRE6EA08-2X/G24K4/V
4WRE10W25-2X/G24K4/V
4WRE6W1-16-2X/G24K4/V
4WRE6W16-21/G24K4/V
4WRE10E50-23/G24K31/A1V
0811404800 4WRPEH10C3B50L-2X/G24K0/A1M
0811404801 4WRPEH10C3B100L-2X/G24K0/A1M
0811404756 4WRPEH10C5B50L-2X/G24K0/A1M
0811404757 4WRPEH10C5B100L-2X/G24K0/A1M
0811404822 4WRPEH10C3B50P-2X/G24K0/A1M
0811404823 4WRPEH10C3B100P-2X/G24K0/A1M
0811404826 4WRPEH10C5B 50P-2X/G24K0/A1M
0811404827 4WRPEH10C5B100P-2X/G24K0/A1M
0811404819 4WRPEH10C3B 50L-2X/G24K0/F1M
0811404817 4WRPEH10C3B100L-2X/G24K0/F1M
0811404758 4WRPEH10C5B 50L-2X/G24K0/F1M
0811404759 4WRPEH10C5B100L-2X/G24K0/F1M
0811404802 4WRPEH10C4B 50L-2X/G24K0/A1M
0811404820 4WRPEH10C4B100L-2X/G24K0/A1M
0811404803 4WRPEH10C1B 50L-2X/G24K0/A1M
0811404821 4WRPEH10C1B100L-2X/G24K0/A1M
0811404824 4WRPEH10C4B 50P-2X/G24K0/A1M
0811404825 4WRPEH10C4B100P-2X/G24K0/A1M
0811404828 4WRPEH10C1B 50P-2X/G24K0/A1M
0811404829 4WRPEH10C1B100P-2X/G24K0/A1M
0811404760 4WRPEH10C4B 50L-2X/G24K0/F1M
0811404761 4WRPEH10C4B100L-2X/G24K0/F1M
0811404762 4WRPEH10C1B 50L-2X/G24K0/F1M
0811404763 4WRPEH10C1B100L-2X/G24K0/F1M
0811404764 4WRPEH10CB 50L-2X/G24K0/A1M
0811404809 4WRPEH10CB100L-2X/G24K0/A1M
0811404765 4WRPEH10CB 50L-2X/G24K0/F1M
Yes, a 25 μm absolute filter (β100 ≥ 75) is mandatory in the supply line to prevent contamination of the valve's internal components.
Yes, water contamination (exceeding 0.1%) can cause corrosion, seal degradation, and clogging. Use water-separating filters and monitor fluid moisture levels.
Follow ISO 4406 Class 18/16/13 (maximum 1300 particles ≥4 μm, 160 particles ≥6 μm, 20 particles ≥14 μm per mL).
Yes, all 4WREE valves meet CE requirements for electromagnetic compatibility (EMC) and machinery safety (Directive 2006/42/EC).
Depressurize the hydraulic system before installation, wear protective gloves and goggles, and ensure the valve is rated for the system's pressure and flow.
Kontak Person: Mr. liyun
Tel: +8615280488899