Produktdetails:
|
| Betriebstemperatur: | -20°C bis +80°C | Hydraulikflüssigkeit: | Mineralöle (HL, HLP), HETG, HEES, HFDU |
|---|---|---|---|
| Montageflansch: | ISO 3019-2 (SAE 2-Loch) | Max. Fließen: | ~117 L/min (bei 2600 U/min) |
| Spitzendruck: | 350 bar |
|
Parameter |
Specification |
|---|---|
|
Manufacturer / Series |
Rexroth A10VSO Series 31 |
|
Order Code |
R910967365 |
|
Full Model |
AA10VS045DFR1/31R-VPA12N00 |
|
Pump Type |
Axial Piston Variable Pump (Swashplate Design, Open Circuit) |
|
Control Type |
DFR1 (Pressure & Flow Control / Load Sensing) |
|
Max. Displacement |
45 cm³/rev |
|
Nominal Pressure |
280 bar |
|
Peak Pressure |
350 bar |
|
Nominal Size |
NG 45 |
|
Rotation Direction |
Right-hand (R, viewed from shaft end) |
|
Shaft Type |
Parallel Keyed Shaft (DIN 6885) |
|
Ports |
S (Suction), B (Pressure), L (Case Drain), X (LS Control) |
|
Port Size |
Code 12 (Metric threads) |
|
Mounting Flange |
ISO 3019-2 (SAE 2-bolt) |
|
Max. Speed |
2600 rpm (at full displacement) |
|
Max. Flow |
~117 L/min (at 2600 rpm) |
|
Seal Material |
FKM (Viton) |
|
Hydraulic Fluid |
Mineral oils (HL, HLP), HETG, HEES, HFDU |
|
Operating Temperature |
-20°C to +80°C |
|
Weight |
Approx. 23.5 kg |
|
Country of Origin |
Germany |
Q1: What is the function of the "DFR1" control?
A: The DFR1 is a combined Pressure and Flow Controller. It provides two key functions:
Pressure Limiting: Acts as a pressure compensator, destrokeing the pump when system pressure reaches the set value.
Load Sensing (Flow Control): Automatically adjusts displacement to maintain a constant pressure differential (Δp) across a downstream orifice, providing load-independent flow control for improved energy efficiency.
Q2: What does the "VPA12N00" suffix indicate?
A: This code defines the mechanical configuration:
V: FKM (Viton) seals, offering superior chemical and temperature resistance.
P: Standard parallel key shaft (DIN 6885).
A12: Port size code 12 (metric threads).
N00: No through-drive (solid shaft end, cannot mount additional pumps on the shaft).
Q3: What is the key difference between this A10VSO45 and the previously mentioned A10VSO28?
A: The primary difference is the displacement size:
A10VSO45: 45 cm³/rev, providing higher flow output (~117 L/min vs ~84 L/min at same speed).
A10VSO28: 28 cm³/rev, smaller size for lower flow requirements.
Both share the same DFR1 control type and Series 31 design.
Q4: What are the X and L ports used for?
A:
X Port (Control): Load-Sensing (LS) Feedback. It connects to the downstream system to sense the load pressure, allowing the pump to adjust its displacement to maintain the set Δp.
L Port (Case Drain): Must be connected directly to the tank. It relieves internal leakage pressure to protect the shaft seal (max backpressure typically 2 bar).
Q5: Can this pump be used in a closed-loop system?
A: No. The A10VSO DFR1 is designed exclusively for open-circuit applications (pump → valve → actuator → tank). For closed-loop hydrostatic transmissions, you would need an A4VG or A2FM series unit.
Ansprechpartner: Mr. liyun