logo
Startseite ProdukteHydraulikpumpe von Rexroth

PV7-1X/63-71RE07MW0-16WG PV7-1X/10-20RE01MD5-10 PV7-1X/25-30RE01MW0-16WG Flügelzellenölpumpe Deutsch Rexroth PV7 Serie Hydraulikpumpe importiert mit Originalverpackung

Ich bin online Chat Jetzt

PV7-1X/63-71RE07MW0-16WG PV7-1X/10-20RE01MD5-10 PV7-1X/25-30RE01MW0-16WG Flügelzellenölpumpe Deutsch Rexroth PV7 Serie Hydraulikpumpe importiert mit Originalverpackung

PV7-1X/63-71RE07MW0-16WG	
PV7-1X/10-20RE01MD5-10
PV7-1X/25-30RE01MW0-16WG Blade oil pump German Rexroth PV7 series hydraulic pump imported with original packaging
PV7-1X/63-71RE07MW0-16WG	
PV7-1X/10-20RE01MD5-10
PV7-1X/25-30RE01MW0-16WG Blade oil pump German Rexroth PV7 series hydraulic pump imported with original packaging PV7-1X/63-71RE07MW0-16WG	
PV7-1X/10-20RE01MD5-10
PV7-1X/25-30RE01MW0-16WG Blade oil pump German Rexroth PV7 series hydraulic pump imported with original packaging

Großes Bild :  PV7-1X/63-71RE07MW0-16WG PV7-1X/10-20RE01MD5-10 PV7-1X/25-30RE01MW0-16WG Flügelzellenölpumpe Deutsch Rexroth PV7 Serie Hydraulikpumpe importiert mit Originalverpackung

Produktdetails:
Herkunftsort: Deutsch
Markenname: Rexroth
Zertifizierung: ISO
Modellnummer: PV7-1X/63-71RE07MW0-16WG PV7-1X/10-20RE01MD5-10 PV7-1X/25-30RE01MW0-16WG
Zahlung und Versand AGB:
Min Bestellmenge: 1
Verpackung Informationen: Holzkiste
Lieferzeit: 2 Wochen
Zahlungsbedingungen: Moneygram, Western Union, T/T, D/A, D/P, l/c
Versorgungsmaterial-Fähigkeit: 100

PV7-1X/63-71RE07MW0-16WG PV7-1X/10-20RE01MD5-10 PV7-1X/25-30RE01MW0-16WG Flügelzellenölpumpe Deutsch Rexroth PV7 Serie Hydraulikpumpe importiert mit Originalverpackung

Beschreibung
Welche Arten von Hydraulikflüssigkeiten sind mit der PV7-Serie kompatibel?: Mineralöl (HLP) und synthetisches Öl (HETG/HEES); Verwenden Sie FKM-Dichtungen für synthetische Flüs Was ist der Flüssigkeitsviskositätsbereich für den Betrieb der PV7-Serie?: 10–1000 mm²/s (Betrieb); 2–1500 mm²/s (Anlauf); Der optimale Bereich liegt bei 16–160 mm²/s
Was ist der Flüssigkeitstemperaturbereich für den Betrieb der PV7-Serie?: -20 bis +80 °C (Betrieb); -40 bis +90 °C (Lagerung) Was ist der Montagestandard für die PV7-Serie?: ISO 3019-2-Flansch; optionale Fußmontage für einige Modelle
Was ist der Gewichtsbereich der direktwirkenden PV7-Serie?: 8–12 kg (je nach Verdrängung)
Hervorheben:

Rexroth PV7 Hydraulik-Flügelzellenpumpe

,

Deutsch importierte Flügelzellenölpumpe

,

Originalverpackung Rexroth PV7 Pumpe

Rexroth PV7 Serie Hydraulik-Flügelzellenpumpe
Ausgewählte Modelle

PV7-1X/63-71RE07MW0-16WG
PV7-1X/10-20RE01MD5-10
PV7-1X/25-30RE01MW0-16WG

Produktübersicht

Deutsche Rexroth PV7 Serie Hydraulik-Flügelzellenpumpe, importiert mit Originalverpackung. Hochleistungs-Ölpumpe mit Flügelzellen, konzipiert für industrielle Hydrauliksysteme.

Technische Daten
Parameter Spezifikation
Modellreihe PV7-1X/10-14RE01MC0-16, PV7-1X/16-20RE01MC0-16, PV7-2X/20-25RE01MC0-16 (typische Modelle)
Verdrängung pro Umdrehung 10-25 cm³/Umdr. (variiert je nach Modell)
Maximaler Betriebsdruck 210 bar (Dauerbetrieb), 250 bar (Spitze)
Maximale Drehzahl 1800-3600 U/min (abhängig von Verdrängung und Fluidviskosität)
Minimale Drehzahl 600 U/min (gewährleistet stabilen Betrieb)
Fluidmedium Mineralölbasiertes Hydraulikfluid (ISO VG 32/46/68 empfohlen)
Fluid-Temperaturbereich -20 °C bis +80 °C (Betrieb); -40 °C bis +90 °C (Lagerung)
Viskositätsbereich 10-1000 mm²/s (Betrieb); 2-1500 mm²/s (Anlauf)
Volumetrischer Wirkungsgrad ≥90% (bei Nenndruck und -drehzahl)
Gesamtwirkungsgrad ≥80% (unter Nennbetriebsbedingungen)
Geräuschpegel ≤65 dB(A) (in 1 m Entfernung unter Nennbetrieb)
Saugdruck -0,8 bar bis +1 bar (absoluter Druck: 0,2-1,1 bar)
Montageart Flanschmontage (ISO 3019-2 Standard), Fußmontage (optional)
Wellenanschluss Keilwellenanschluss (ISO 4162 Standard) oder Passfedernutwelle (anpassbar)
PV7-1X/63-7
<div class=Verfügbare Modelle
PV7-1X/63-71RE07MC3-16
PV7-1X/100-118RE07MD3-16
PV7-1X/63-71RE07MW0-16WG
PV7-1X/10-20RE01MD5-10
PV7-1X/25-30RE01MW0-16WG
PV7-1X/40-45RE37MW5-16WG
PV7-1X/100-118RE07MC5-16WG
PV7-1X/63-94RE07MC7-08WG
PV7-1X/40-45RE37MW6-16WH
PV7-1X/100-118RE07MD6-16
PV7-1X/40-45RE37MC5-16WG
PV7-1X/100-118RE07MC0-16
PV7-1X/63-71RE07MD0-16
PV7-1X/40-45RE37MC0-16-P90
PV7-1X/25-30RE01MC0-16-P100Q38
PV7-1X/100-150RE07MC0-08-A464
PV7-1X/100-118RE07MD0-16
PV7-1X/10-14RE01MN0-16
PV7-1X/40-45RE37MC5-16
PV7-1X/100-118RE07MC5-16
PV7-1X/25-30RE01KC3-16
PV7-1X/10-20RE01MC5-10WG
PV7-1X/25-30RE01MW0-16
PV7-1X/16-20RE01MD3-16
PV7-1X/16-20RE01MC0-16-P110
PV7-1X/40-45RE37KD0-16-C3.1
PV7-1X/63-71RE07MC5-16WH
PV7-1X/16-30RE01KC0-08
PV7-1X/10-14RE01MD5-16
PV7-1X/63-71RE07MC6-16
PV7-1X/16-20RE01KD0-16
PV7-1X/10-14RE01MW0-16
PV7-1X/63-71RE07MC0-16-C3.1
PV7-1X/16-30RE01MW0-08WH
PV7-1X/100-150RE07MC0-08-A446
PV7-1X/25-30RE01MC5-16WG
PV7-1X/10-20RE01MC0-10-A497
PV7-1X/100-150RE07KC0-08
PV7-1X/100-150RE07MD5-08
PV7-1X/25-45RE01MC0-08-P25Q50
PV7-1X/40-71RE37MC5-08
PV7-1X/10-14RE01KD0-16
PV7-1X/16-20RE01MC0-16-P120
PV7-1X/100-150RE07MW0-08WH
PV7-1X/16-20RE01MC5-16WG
PV7-1X/10-20RE01MW0-10WH
PV7-1X/63-94RE07KD0-08
PV7-1X/63-71RE07MW0-16WH
PV7-1X/63-71RE07MC7-16WH
PV7-1X/40-45RE37MC0-16
PV7-1X/63-94RE07MC0-08-P80Q114
PV7-1X/40-45RE37MC5-16WH
PV7-1X/10-14RE01KN0-16
PV7-1X/25-30RE01MC5-16WH-A234
PV7-1X/63-71RE07KC0-16
PV7-1X/10-20RE01MC3-10
PV7-1X/16-20RE01MN0-16
PV7-1X/25-45RE01MW0-08WH
PV7-1X/63-71RE07MN0-16
PV7-1X/63-71RE07KD0-16
PV7-1X/16-20RE01MC8-16
PV7-1X/40-71RE37MW0-08WH
PV7-1X/40-45RE37MD0-16-P50Q36
PV7-1X/40-45RE37MC7-16WG
PV7-1X/100-118RE07MN5-16
PV7-1X/25-45RE01MC7-08WG
PV7-1X/63-71RE07MC7-16
PV7-1X/100-150RE07MC3-08
PV7-1X/40-45RE37KC0-16
PV7-1X/63-94RE07MC5-08
PV7-1X/16-20RE01MC0-16-P60Q26
PV7-1X/16-20RE01MC5-16
PV7-1X/40-71RE37MC5-08WG
PV7-1X/25-45RE01MC7-08
PV7-1X/25-30RE01MW5-16WH
PV7-1X/10-20RE01MD0-10
PV7-1X/63-71RE07MD0-16-Q90
PV7-1X/16-30RE01MC3-08
PV7-1X/100-150RE07MC7-08
PV7-1X/100-118RE07MN0-16
PV7-1X/10-20RE01MC5-10
PV7-1X/25-30RE01MC5-16WH-A234
PV7-1X/100-150RE07MC5-08WH
PV7-1X/25-30RE01MW0-16WH
PV7-1X/10-20RE01MC7-10WH
PV7-1X/25-45RE01MC5-08
PV7-1X/40-45RE37MC8-16
PV7-1X/16-20RE01MW0-16WH
PV7-1X/16-20RE01MC3-16-P50Q25
PV7-1X/100-118RE07KC0-16
PV7-1X/40-71RE37MC5-08WH
PV7-1X/100-118RE07MC6-16
PV7-1X/40-71RE37MC3-08
PV7-1X/40-71RE37MC7-08WH
PV7-1X/10-14RE01MW0-16WH
PV7-1X/10-20RE01MC3-10-A497
PV7-1X/16-20RE01MC3-16
PV7-1X/16-20RE01MC5-16WH
PV7-1X/63-71RE07MC3-06-A460
PV7-1X/16-30RE01MC5-08WH
PV7-1X/10-14RE01MC0-16-P100
PV7-1X/63-94RE07MC5-08WH
PV7-1X/10-14RE01MC3-16
PV7-1X/40-45RE37MD0-16
PV7-1X/100-118RE07MC7-16WH
PV7-1X/25-45RE01MC5-08WH
PV7-1X/16-20RE01MC0-16
PV7-1X/63-71RE07MC5-16WG
PV7-1X/63-71RE07KC3-16
PV7-1X/10-20RE01MC5-10WH
PV7-1X/16-20RE01MC7-16
PV7-1X/10-14RE01MC7-16
PV7-1X/63-94RE07MC0-08
PV7-1X/16-20RE01MC0-16-P100Q29
PV7-1X/25-30RE01MC0-16-P100Q36
PV7-1X/40-45RE37MW5-16WH
Häufig gestellte Fragen
Wie ist die Ansprechzeit der PV7-2X Verstellpumpe bei der Durchflussanpassung?

Die Ansprechzeit liegt unter Nennbetriebsbedingungen in der Regel innerhalb von 0,1-0,3 Sekunden, was den dynamischen Anpassungsanforderungen der meisten industriellen Hydrauliksysteme gerecht werden kann.

Können die Pumpen der PV7-Serie in Wasser-Glykol-Hydrauliksystemen eingesetzt werden?

Ja, aber es sind kundenspezifische Modelle mit speziellen Dichtungsmaterialien (wie Nitrilkautschuk oder Fluorkautschuk) erforderlich; gewöhnliche Modelle können nicht direkt verwendet werden, um ein Aufquellen und Versagen der Dichtungen zu vermeiden.

Was sind die Ursachen für einen zu schnellen Temperaturanstieg der Pumpe der PV7-Serie?

Häufige Ursachen sind eine zu hohe Systemdruckeinstellung, schlechte Wärmeableitung des Hydrauliköltanks, unzureichender Ölfluss, hohe Ölviskosität oder starke innere Reibung der Pumpe aufgrund von Komponentenverschleiß.

Wie identifiziert man die Modellspezifikationen der Pumpe der PV7-Serie?

Der Modellcode enthält Verdrängung, Steuerungstyp, Montageart und andere Informationen; z. B. PV7-1X/10-14RE01MC0-16 bezeichnet eine Pumpe mit fester Verdrängung mit einer Verdrängung von 10-14 cm³/Umdr., Druckkompensationsregelung und einem Standard-Montageflansch.

Kann die Pumpe der PV7-Serie in einem geschlossenen Hydrauliksystem verwendet werden?

Sie ist hauptsächlich für offene Hydrauliksysteme konzipiert; wenn sie in einem geschlossenen System verwendet werden soll, muss sie mit einer Ladepumpe und einem Kühlsystem ausgestattet sein, um Öl nachzufüllen und Wärme abzuführen.

Kontaktdaten
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.

Ansprechpartner: Mr. liyun

Telefon: +8615280488899

Senden Sie Ihre Anfrage direkt an uns (0 / 3000)