logo
Startseite ProdukteMOOG-Servoventil

Original MOOG Servo Valve with 25cm Nominal Diameter and -20°C to 80°C Temperature Range for Electro-Hydraulic Directional Control

Ich bin online Chat Jetzt

Original MOOG Servo Valve with 25cm Nominal Diameter and -20°C to 80°C Temperature Range for Electro-Hydraulic Directional Control

Original MOOG Servo Valve with 25cm Nominal Diameter and -20°C to 80°C Temperature Range for Electro-Hydraulic Directional Control
Original MOOG Servo Valve with 25cm Nominal Diameter and -20°C to 80°C Temperature Range for Electro-Hydraulic Directional Control Original MOOG Servo Valve with 25cm Nominal Diameter and -20°C to 80°C Temperature Range for Electro-Hydraulic Directional Control

Großes Bild :  Original MOOG Servo Valve with 25cm Nominal Diameter and -20°C to 80°C Temperature Range for Electro-Hydraulic Directional Control

Produktdetails:
Herkunftsort: Deutschland
Markenname: MOOG
Zertifizierung: ISO
Modellnummer: D664-4714 D664Z4306K D664Z4382K D765-019-5 D765-1048-5 D765-1603-5 D791-5008 D791-5045 D791-5021 D79
Zahlung und Versand AGB:
Min Bestellmenge: 1
Preis: 2
Verpackung Informationen: Holzkiste
Lieferzeit: 2 Wochen
Zahlungsbedingungen: Moneygram, Western Union, T/T, D/P, D/A, L/C.
Versorgungsmaterial-Fähigkeit: 30

Original MOOG Servo Valve with 25cm Nominal Diameter and -20°C to 80°C Temperature Range for Electro-Hydraulic Directional Control

Beschreibung
Verwendung: Öl Certifisaarion: ISO9001
Temperaturbereich: -20 ° C bis 80 ° C. Transportpaket: Holzkiste
Flüssigkeitskompatibilität: Mineralöl Typ: Axialkolbenpumpe
Pumpwellenposition: horizontal Zustand: Neu
Einlassverbindung: Eingefurdet oder flanscht Fabrik: Hersteller
Hervorheben:

Original MOOG Servo Valve

,

25cm Nominal Diameter Electro-Hydraulic Directional Valve

,

-20°C to 80°C Temperature Range Proportional Flow Control Valve

MOOG Servo Electro-Hydraulic Directional Valve
Product Models

D664-4714, D664Z4306K, D664Z4382K, D765-019-5, D765-1048-5, D765-1603-5, D791-5008, D791-5045, D791-5021, D792-5002

Product Image
Original MOOG Servo Valve with 25cm Nominal Diameter and -20°C to 80°C Temperature Range for Electro-Hydraulic Directional Control 0
Technical Specifications
Specification Value
Nominal Diameter 25cm
Quantity Available 88 units
Custom Processing Support Yes
Origin Germany
Material Cast Iron
Functional Purpose Building Materials Industry
Color Blue
Packaging Boxed
Operating Temperature 36°C
Dimensions 30×40×70 cm
Type Valve
Construction Steel Structure
Compatible Models

Original MOOG D653-2709E, D656Z130, D661 series (1062E, 1718, 1962E, 2057, 205A, 318A, 363 series, 3702E, 4020B, 423A, 4491E, 450 series, 473B, 4744, 4793, 515A, 5718, 5729), D661Z series, D662 series, D663 series, D664 series, D665 series, D682Z series

Frequently Asked Questions
What are the key installation requirements?

Proper installation is critical for performance and longevity:

  • Filtration: Install a precision filter with a rating of 5 microns or less upstream of the servo valve. The hydraulic fluid cleanliness should be maintained at a maximum ISO DIS 4406 Code 16/13, with Code 14/11 recommended.
  • System Flushing: Before installing the servo valve, the entire hydraulic system must be thoroughly flushed to remove contaminants. Use a flushing manifold and circulate fluid under conditions simulating normal operation.
  • Mounting: The valve can be mounted in any orientation, ensuring port alignments match the manifold. The mounting surface should be clean, smooth, and flat. Use the specified screws and torque them to 96 inch-pounds.
  • Connections: Use O-ring seal connections (e.g., SAE J1926) and avoid welded fittings. Prefer crimped or 24-degree cone type connections.
What are common faults and how can I troubleshoot them?

Common faults can be categorized as follows:

  • Electrical Faults: Include power supply failure, cable damage, or poor contact. Check the supply voltage, cables, and connectors.
  • Mechanical Failures: Such as a stuck valve spool, damaged springs, or worn seals. Regular inspection, cleaning, lubrication, and part replacement are necessary.
  • Hydraulic Faults: Including oil contamination, low oil level, or oil leaks. Regularly replace and filter the oil, check oil levels, and repair leaks.
  • Valve Oscillation: Unstable operation may be caused by issues with the servo valve's resolution, wear of the valve port, or incorrect control system parameters.
Troubleshooting Chart
Potential Trouble Probable Cause
Servovalve does not follow input command 1. Open coil or coil leads.
2. Clogged inlet filter.
Poor response 1. Clogged inlet orifices or nozzles.
2. Partially clogged filter.
3. "Sticky" spool.
No response to electrical signal Shorted coil assembly.
Low flow gain 1. Incorrect null adjustment.
2. Partially plugged orifice or filter.
What does daily maintenance involve?

Routine maintenance focuses on preventing common faults:

  • Hydraulic Fluid: Maintain the recommended cleanliness level. Change the oil regularly (e.g., every six months) and keep the oil temperature within the 40°C to 50°C range.
  • Filters: Monitor the pressure drop across filters and replace elements periodically or when the pressure drop becomes excessive.
  • General Inspection: Regularly check for oil leaks, inspect the valve for unusual noises or vibrations, and ensure electrical connections are secure.
  • Sealed Tank: The hydraulic reservoir should be sealed and equipped with an air breather and a magnetic filter.