Rexroth Germany Quantitative Gear Pump with 280 bar Pressure Rating 12 Months Warranty and 100% Tested Performance Rexroth Germany Quantitative Gear Pump with 280 bar Pressure Rating 12 Months Warranty and 100% Tested Performance Rexroth Germany Quantitative Gear Pump with 280 bar Pressure Rating 12 Months Warranty and 100% Tested Performance

Großes Bild :  Rexroth Germany Quantitative Gear Pump with 280 bar Pressure Rating 12 Months Warranty and 100% Tested Performance

Produktdetails:
Herkunftsort: Deutschland
Markenname: Rexroth
Zertifizierung: ISO
Modellnummer: PGH4-2X/100RE07WU2 PGH4-2X/040LF11VK0 PGF2-2X/013RA20VP2 PGF2-2X/006RL20VM PGH5-3X/250RE07VE44
Zahlung und Versand AGB:
Min Bestellmenge: 1
Preis: 2
Verpackung Informationen: Holzkiste
Lieferzeit: 2 Wochen
Zahlungsbedingungen: Moneygram, Western Union, T/T, D/P, D/A, L/C.
Versorgungsmaterial-Fähigkeit: 100

Rexroth Germany Quantitative Gear Pump with 280 bar Pressure Rating 12 Months Warranty and 100% Tested Performance

Beschreibung
WhatsApp: +85267220981 Drehung: 0,2-CP kann umgekehrt transportiert werden
Gewicht: 5,9 kg - 16,5 kg Steuertyp: Druck- oder Strömungskompensator
Flüssigkeitskompatibilität: Mineralöl Skype: Sensenhenhao
Typ: Axialkolbenpumpe Wellentyp: Verspleißt oder geküsst
Rotationsgeschwindigkeit: 1800 - 3000 U / min Montagetyp: Flansch oder Fuß
Geschwindigkeit: Hydrauliköl, Wasserethylenglykol Druckbewertung: 280 bar
Hervorheben:

280 bar Quantitative Gear Pump

,

12 Months Warranty Gear Pump

,

100% Tested Internal Gear Pump

Rexroth PGH Series Internal Gear Pumps
Product Models

PGH4-2X/100RE07WU2
PGH4-2X/040LF11VK0
PGF2-2X/013RA20VP2
PGF2-2X/006RL20VM
PGH5-3X/250RE07VE4

Product Specifications
Brand Name Rexroth
Place of Origin Germany
Warranty 12 Months
Application Machinery Repair Shops
Material Iron
Condition Original
Quality 100% Tested Great Performance
Certification ISO
Feature Long Life, Low Noise
Function Filter Diesel Oil
Power Hydraulic Power
Rexroth Germany Quantitative Gear Pump with 280 bar Pressure Rating 12 Months Warranty and 100% Tested Performance 0
Available Models in Stock
  • PGH3-2X/016RE07VU2
  • PGH4-2X/020RE11VU2
  • PGH4-2X/025RE11VU2
  • PGH4-2X/032RE11VU2
  • PGH4-2X/040RE11VU2
  • PGH4-2X/050RE11VU2
  • PGH5-3X/063RE11VU2
  • PGH5-3X/080RE11VU2
  • PGH5-3X/100RE11VU2
  • PGH5-3X/125RE11VU2
  • PGH5-3X/160RE11VU2
  • PGH5-2X/080RE11VU2
  • PGH5-2X/125RE11VE4
Technical Specifications
  • Model specifications: 2, 3, 4, and 5 2X series
  • Maximum working pressure: 350 bar
  • Maximum displacement: 6-250cm³
  • Low operating noise and minimal vibration
  • Sealing gap compensation enables efficient operation even at low speeds and low viscosities
  • Suitable for various speeds and viscosity ranges
  • All installation and rated size components can be connected
  • Can be connected and used with vane pumps and axial piston pumps
Frequently Asked Questions
1. What core advantages make the PGH Series Gear Pumps suitable for industrial use?

The PGH Series stands out for its high pressure stability (supporting working pressures up to 250 bar for most models), compact structural design (saving installation space in hydraulic systems), and low noise operation (noise levels as low as 65 dB under rated conditions), making it ideal for continuous-duty industrial scenarios.

2. What precautions should be taken during the installation of PGH Series Gear Pumps?
  • Ensure the pump's rotational direction matches the system's requirements (reverse rotation can cause internal component damage).
  • Keep the suction line length within 1 meter and avoid sharp bends to prevent insufficient oil suction.
  • Tighten the flange bolts to the torque specified in the manual (typically 18-22 N*m for standard models) to avoid oil leakage or housing deformation.
3. How to resolve abnormal noise from a PGH Series Gear Pump during operation?

First, check if the hydraulic oil level is too low (topping up to the standard level if needed); second, inspect for air bubbles in the oil circuit (bleeding the system to remove air); finally, check if the bearing is worn (replacing the bearing if there is excessive radial play).

4. What is the recommended hydraulic oil cleanliness level for PGH Series Gear Pumps?

To avoid clogging internal oil passages or accelerating wear, the hydraulic oil must meet a NAS 8级 (NAS Class 8) cleanliness level. Additionally, use oil with anti-foaming and anti-rust additives to extend the pump's service life.

5. Can PGH Series Gear Pumps be used interchangeably with other Rexroth gear pump series?

No, direct interchange is not recommended. The PGH Series has unique mounting dimensions (e.g., flange size, shaft diameter) and flow-pressure curves that differ from other series (such as the PGH4 vs. PGK Series). Interchange may lead to system mismatch or pump failure. Always refer to the Rexroth product catalog for compatibility.