logo
Thuis ProductenRexroth hydraulische klep

R983032399 2FRM6A36-2X/10QRV-IN001 Rexroth handmatig toerentalregulerend ventiel

Ik ben online Chatten Nu

R983032399 2FRM6A36-2X/10QRV-IN001 Rexroth handmatig toerentalregulerend ventiel

R983032399  2FRM6A36-2X/10QRV-IN001 Rexroth manual speed control valve
R983032399  2FRM6A36-2X/10QRV-IN001 Rexroth manual speed control valve

Grote Afbeelding :  R983032399 2FRM6A36-2X/10QRV-IN001 Rexroth handmatig toerentalregulerend ventiel

Productdetails:
Plaats van herkomst: Duitsland
Merknaam: Rexroth
Certificering: ISO
Modelnummer: R983032399 2FRM6A36-2X/10QRV-IN001
Betalen & Verzenden Algemene voorwaarden:
Min. bestelaantal: 1
Verpakking Details: houten kist
Levertijd: 2 weken
Betalingscondities: Western Union,T/T,D/P,D/A,L/C
Levering vermogen: 100

R983032399 2FRM6A36-2X/10QRV-IN001 Rexroth handmatig toerentalregulerend ventiel

beschrijving
Nominale maat​: NG6 (D03 / ISO 4401-03-02-0-05). Max. Bedrijfsdruk (P-poort)​: 315 bar​
Max. Afvoerdruk (Y-poort)​: 160 bar​ (aanbevolen nul tegendruk naar tank) Instelbaar stroombereik: 0,5 – 10 L/min​ (Code /10Q = max. debiet 10 L/min)
Gas richting: A → A₁​ (meter-in); Gratis retour A₁ → A via geïntegreerde cheque ("A"-versie)
Markeren:

Rexroth-handmatig toerentalregelventiel

,

Rexroth-hydraulisch bedieningsklep

,

Rexroth klep met garantie

Parametercategorie

Parameter

Specificatie

Algemene informatie- Ik weet het niet.

Merk / model- Ik weet het niet.

Rexroth, Duitsland,2FRM6A36-2X/10QRV- Ik weet het niet.


Bestelcode (materiaal nr.)- Ik weet het niet.

R983032399


Typ van de klep- Ik weet het niet.

Tweeweg drukcompensatie-stroomregelklep (sandwichplaat)

Prestatieparameters- Ik weet het niet.

Nominale grootte- Ik weet het niet.

NG6 (D03 / ISO 4401-03-02-0-05)- Ik weet het niet.


Maximale werkdruk (P-poort)- Ik weet het niet.

315 bar- Ik weet het niet.


Max. Afvoerdruk (Y-poort)- Ik weet het niet.

160 bar(aanbevolen nul tegendruk op de tank)


Verstelbaar stroombereik- Ik weet het niet.

0.5 10 l/min(Code /10Q = maximale doorstroming 10 L/min)


Gasrichting- Ik weet het niet.

A → A1(Meter-In); Gratis retour A1 → A via geïntegreerde controle ("A"-versie)


Vergoeding- Ik weet het niet.

Geïntegreerde drukcompensator (houdt ∆P over de opening constant, typ. 3 ‰ 5 bar)

Mechanische interface- Ik weet het niet.

Montage-stijl- Ik weet het niet.

Sandwichplaat(geïnstalleerd tussen de richtingventiel NG6 en de subplaat)


Montagebouten- Ik weet het niet.

4 × M5 (ISO 4762, klasse 10.9), koppel ~ 8 ‰ 10 Nm dwarspatroon


Tipe aanpassing- Ik weet het niet.

Spindel met schaal en slotnoot (code 36) + beschermende dop


Drainagevereiste- Ik weet het niet.

Externe afvoerpoortY→ Tank (speciale lijn, nul tegendruk)


Gewicht- Ik weet het niet.

Bij benadering.10,4 kg- Ik weet het niet.

Media en milieu- Ik weet het niet.

Gezegelmateriaal- Ik weet het niet.

FKM (Viton®)​ — suffixV- Ik weet het niet.


Compatibele vloeistoffen- Ik weet het niet.

Minerale oliën (HL/HLP), HFC's (waterglycol), HFD's (fosfaatester met FKM)


Werktemperatuurbereik- Ik weet het niet.

-20°C tot +80°C(met FKM-zegels)


Vloeistofzuiverheid- Ik weet het niet.

ISO 440617/15/12of een reiniger (fijn opening ️ strengere filtratie vereist)


Bijzondere opmerking- Ik weet het niet.

IN001= Referentie van de partij voor interne inspectie (geen functioneel verschil)

R983032399 2FRM6A36-2X/10QRV-IN001 Rexroth handmatig toerentalregulerend ventiel 0

R983032407 2FRM6B36-2X/0.6QRV-IN001
R983032408 2FRM6B36-2X/1.5QMV-IN001
R983032409 2FRM6B36-2X/1.5QRV-IN001
R983032421 2FRM6B36-2X/3QMV-IN001
R983032410 2FRM6B36-2X/3QRV-IN001
R983032411 2FRM6B36-2X/6QMV-IN001
R983032412 2FRM6B36-2X/6QRV-IN001
R983032413 2FRM6B36-2X/10QMV-IN001
R983032414 2FRM6B36-2X/10QRV-IN001
R983032415 2FRM6B36-2X/16QMV-IN001
R983032416 2FRM6B36-2X/16QRV-IN001
R983032417 2FRM6B36-2X/25QMV-IN001
R983032418 2FRM6B36-2X/25QRV-IN001
R983032419 2FRM6B36-2X/32QMV-IN001
R983032420 2FRM6B36-2X/32QRV-IN001

R900205577 2FRM6B36-3X/0,2QMV
R900205509 2FRM6B36-3X/10QRV
R900205514 2FRM6B36-3X/32QMV
R900209927 2FRM6B76-34/10QRV
R900205521 2FRM6B76-3X/16QMV
R900205523 2FRM6B76-3X/25QMV
R900205510 2FRM6B36-3X/16QMV
R900216559 2FRM6A76-3X/16QMV
R900205512 2FRM6B36-3X/25QMV
R900986124 2FRM6A36-3X/32QMV
R900205517 2FRM6B36-3X/3QRV
R900205515 2FRM6B36-33/32QRV
R900205519 2FRM6B36-32/6QRV
R900205511 2FRM6B36-33/16QRV
R900205513 2FRM6B36-32/25QRV
R900205508 2FRM6B36-3X/10QMV

Vragen die vaak worden gesteld

V1: Wat is het verschil tussen "A" en "B" versies van 2FRM6?

A:

  • 2FRM6A...= VersperringA → A1richting (meter-in aan poort A-zijde). gestapeld tussen richtingventiel en subplaat op de poort A.

  • 2FRM6B...= VersperringB → B1richting (meter-in aan poort B-zijde).

    Voor onafhankelijke snelheidsregeling op zowel uitbreiding als intrekking worden meestal een A-versie en een B-versie gestapeld.

V2: Waarom is een externe afvoer (Y-poort) nodig en wat als ik hem niet aansluit?

A:Dedrukcompensator spoelDe tank moet een referentiedruk hebben.De Y-poort moet rechtstreeks naar het reservoir worden geleid met nul tegendrukAls de Y-poort geblokkeerd is of tegendruk wordt waargenomen, kan de compensator niet worden gereguleerd → de stroom wordt drukgevoelig en onstabiel.

V3: Hoe verschilt dit van een Z2FS6-naaldgasklep?

A:De2FRM6 heeft een drukcompensatorhet handhaven van constante ∆P over het meetgat, dusde ingestelde stroom blijft constant ondanks veranderingen van de belastingdrukEen Z2FS6 is een eenvoudige naaldversneller ∆ de stroom varieert met ∆P. Gebruik 2FRM wanneer een constante aandrijvingssnelheid onder variabele belasting van cruciaal belang is; gebruik Z2FS voor basisversnellers die rekening houden met de kosten.

V4: Wat betekent de "10Q"-stroomcode in de praktijk?

A:- Ik weet het niet./10Qstelt demaximaal instelbare stroom tot 10 L/minSelecteer de Q-code die overeenkomt met uw vereiste maximale stroom ∙ een kleiner Q-bereik (/1.5Q, /3Q, /6Q) geeft een fijnere aanpassingsresolutie.Indien uw toepassing > 10 l/min op NG6 vereist, zie NG10 (2FRM10).

V5: Waarom is FKM (Viton) -zegels? NBR niet voldoende?

A:DeV-suffix = FKM-zegels, vereist voor:

  • Temperaturen boven +70°C (tot +80°C)

  • Waterglycol (HFC)offosfaatester (HFD)brandwerende vloeistoffen

    Voor standaard minerale olie (HL/HLP) bij normale temperaturen is NBR aanvaardbaar.De FKM-versie (dit onderdeel R983032399) biedt een bredere compatibiliteit met vloeistoffen en een hogere temperatuurscategorie select op basis van uw werkelijke hydraulische vloeistof.

Contactgegevens
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.

Contactpersoon: Mr. liyun

Tel.: +8615280488899

Direct Stuur uw aanvraag naar ons (0 / 3000)