Productdetails:
|
| Max. Bedrijfsdruk: | 315 bar | Afmeting afdekplaat: | Voor patroonholte van 25 mm |
|---|---|---|---|
| Model: | LFA 25 D BW2-7X/315 | Bestelnr.: | R900912810 |
| Elektrische aansluiting: | DIN 43650-connector (typisch) |
|
Parameter |
Specification |
|---|---|
|
Model |
LFA 25 D BW2-7X/315 |
|
Order No. |
R900912810 |
|
Type |
Cover Plate Assembly for Cartridge Valve |
|
Function |
Manifold Cover with Integrated Control Valve |
|
Cover Plate Size |
For 25 mm Cartridge Cavity |
|
Integrated Valve Type |
Solenoid-Operated, Pilot-Operated Directional Valve |
|
Max. Operating Pressure |
315 bar |
|
Solenoid Type |
Proportional or Switching Solenoid (Code dependent) |
|
Port Configuration |
P (Pressure), T (Tank), A, B (Actuator Ports) |
|
Mounting Interface |
Mounts onto ISO 4401 (CETOP 5) or equivalent manifold surface |
|
Electrical Connection |
DIN 43650 connector (typical) |
|
Control Function |
Controls the pilot stage of the main cartridge valve |
|
Standard Seal Material |
FKM (Viton) |
|
Suitable Media |
Mineral Oils (HL, HLP per DIN 51524) |
|
Media Temperature |
-20°C to +80°C |
|
Special Feature |
Integrates electrical control directly onto the manifold, controlling a large cartridge valve underneath. |
![]()
| R900976999 LC50B05E7X/V |
| R900977395 LC16B10E7X/V |
| R900977714 LC40B00E7X/V |
| R900978750 LC63DB80E7X/V |
| R900979055 LC63A10D7X/V |
| R900979798 LC63A05E7X/V |
| R900979962 LC40A40D7X/V |
| R901003149 LC32B20E7X/V-004 |
| R901004979 LC32DB40B7X/V |
| R901013635 LC40B05D7X/V |
| R901078215 LC16B05D7X/V |
| R901079561 LC32DB50D7X/V |
| R901083347 LC32B10D7X/-010 |
| R901090510 LC63DB20D7X/V |
| R901107567 LC100B20E6X/V |
| R901108714 LC80B20D6X/V |
| R901108718 LC100B20D6X/V |
| R901116294 LC25B02E7X/V |
| R901131754 LC32B20D7X/V |
| R901174969 LC63B20D7X/V |
| R901174986 LC63B40D7X/V |
| R901184323 LC32DB05D7X/V |
| R901200472 LC40DB30D7X/ |
| R978007661 LC32DB50D7X/ |
| R978013085 LC63B05D7X/V |
| R900525698 LC100A40E6X/ |
| R900527337 LC80A20D6X/ |
| R900533027 LC80A10E6X/ |
| R900533784 LC80B20E6X/ |
| R900533785 LC80B40E6X/ |
| R900534131 LC80A10D6X/ |
| R900539872 LC100B05D6X/ |
| R900546788 LC80B05E6X/ |
| R900547814 LC100B40E6X/ |
| R900548067 LC80DB40D6X/V |
| R900551759 LC100A20E6X/ |
| R900553674 LC100B05E6X/ |
| R900554857 LC80A05D6X/ |
| R900560360 LC80B00E6X/ |
| R900562672 LC100A40D6X/ |
| R900563206 LC80B10E6X/ |
| R900568486 LC80B00D6X/ |
| R900569389 LC80A05E6X/ |
| R900570128 LC80A00E6X/ |
| R900572880 LC100A10E6X/ |
| R900577207 LC80A05E6X/V |
| R900617469 LC80B40E6X/V |
| R900617503 LC25B40D7X/V |
| R900618376 LC40B10E7X/B60 |
| R900705510 LC63A40D7X/V |
| R900705728 LC40DB20D7X/V |
| R900705729 LC40DB05E7X/V |
| R900706494 LC40B10E7X/V |
| R900706552 LC50DB40D7X/V |
| R900710125 LC50A40E7X/V |
| R900711883 LC63B40E7X/V |
| R900716767 LC50A05E7X/V |
| R900727900 LC63A40E7X/V |
| R900729521 LC50B40E7X/V |
| R900730774 LC63DB20E7X/V |
Q: What is the primary function of this LFA cover plate?
A: The LFA cover plate is not a flow control valve itself. It is a control module that mounts onto the surface of a hydraulic manifold. Its primary function is to house and provide the pilot control valve for a much larger, underlying screw-in cartridge valve (e.g., a proportional throttle, pressure, or directional valve). It integrates electrical control directly onto the manifold, simplifying the system and eliminating external pilot piping.
Q: How does this cover plate work with the main cartridge valve?
A: The cover plate mounts over the cavity containing the main cartridge valve. It provides the pilot pressure supply (P), tank return (T), and control ports (A, B) that connect directly to the pilot stage of the cartridge valve beneath it. The small integrated directional valve inside the cover plate switches or modulates this pilot flow, thereby controlling the operation of the large, high-power main valve. It acts as the "brain" controlling the "muscle".
Q: What does the "BW2-7X" code in the model signify?
A: This is a Rexroth detailed variant code for the integrated control valve. "BW2" likely specifies the type of valve (e.g., a wet-pin solenoid directional valve) and its performance characteristics. "7X" defines the control configuration—in this context, the "X" often refers to the standard external control, and "7" may indicate a specific spool type or voltage option. The exact function (e.g., 4/3-way, 4/2-way) is defined by this code.
Q: Does this unit require an external power supply and control signal?
A: Yes. The integrated solenoid valve requires a standard electrical power supply (e.g., 24V DC, as indicated by common codes) connected via its DIN 43650 plug. It also requires a control signal from a machine's PLC. For a simple on/off valve, this is a digital signal. If it's a proportional valve ("BW" often indicates proportional), it requires an analog command signal (0-10V, 4-20mA) from a compatible amplifier card.
Q: What are the advantages of using a cover plate like this versus a traditional setup?
A: The main advantages are: 1) Compactness: Eliminates bulky external pilot valves and piping. 2) Reliability: Reduces potential leak points by using internal manifold drilling. 3) Performance: Short pilot lines enable faster response times for the main valve. 4) Cleanliness: Presents a clean, integrated appearance and protects the pilot valve. 5) Serviceability: The entire control module can be unbolted for maintenance or replacement without disturbing the main valve or manifold plumbing.